Wellea Monoblock DF

Monoblock Heat pump - Three-phase

Airwell low temperature air/water Monoblock heat pump - Wellea Monoblock DF

Its benefits

  • RCW29 remote control included
  • Water at up to 60 °C at outdoor temperatures down to -10 °C
  • Compatible with all transmitter types
  • High power available

The + "sustainable development":

  • High energy class A+++.

The + "user":

  • Compatible with all transmitters.
  • Great flexibility of use.
  • Perfect for replacing an oil or gas boiler.

The + "installer":

  • Customizable water program.
  • Manage the entire heating circuit, thanks to the many available
  • connections.

The + "technology":

  • Operates at outdoor temperatures down to -25 °C.
  • HP Keymark certified.
  • Characteristics products
  • RT 2012 RT 2012
    Cooling mode operational up to 46°C outdoors Cooling mode operational up to 46°C outdoors
    Floor heating Floor heating
    High-temperature radiator High-temperature radiator
    Low-temperature radiator Low-temperature radiator
    Boiler back-up Boiler back-up
    CEE CEE
    Ma Prime Renov' (only in France) Ma Prime Renov' (only in France)
    Unités intérieures AW-WHPMA18-H93 AW-WHPMA22-H93 AW-WHPMA26-H93 AW-WHPMA30-H93
    Unités extérieures 1
    ~230V - 50Hz
    Unités extérieures 3
    ~400V - 50Hz - N
    Cooling
    Cooling::Air 35°C - Water ind. 12°C /out. +7°C - Heating capacity kW 17.00 21.00 26.00 29.50
    Cooling::Air 35°C - Water ind. 12°C /out. +7°C - Rated power input kW 5.57 7.12 9.63 11.57
    Cooling::Air 35°C - Water ind. 12°C /out. +7°C - EER 3.05 2.95 2.70 2.55
    Cooling::Air 35°C - Water ind. 23°C /out. +18°C - Heating capacity kW 18.50 23.00 27.00 31.00
    Cooling::Air 35°C - Water ind. 23°C /out. +18°C - Rated power input kW 3.90 5.00 6.28 7.75
    Cooling::Air 35°C - Water ind. 23°C /out. +18°C - EER 4.75 4.60 4.30 4.00
    Heating
    Heating::Air+7°C - Water 30/35°C - Heating capacity kW 18.30 22.30 26.30 29.93
    Heating::Air+7°C - Water 30/35°C - Rated power input kW 3.96 5.13 6.50 8.02
    Heating::Air+7°C - Water 30/35°C - COP 4.63 4.35 4.05 3.73
    Heating::Air-7°C - Water 30/35°C - Heating capacity kW 18.00 21.00 22.00 23.00
    Heating::Air-7°C - Water 30/35°C - Rated power input kW 6.67 8.08 8.80 9.39
    Heating::Air-7°C - Water 30/35°C - COP 2.70 2.60 2.50 2.45
    Heating::Air-7°C - Water 47/55°C - Heating capacity kW 18.10 22.10 26.06 29.68
    Heating::Air-7°C - Water 47/55°C - Rated power input kW 6.63 8.33 10.72 12.97
    Heating::Air-7°C - Water 47/55°C - COP 2.73 2.65 2.43 2.29
    Heating::Air+7°C - Water 47/55°C - Heating capacity kW 10.70 13.50 16.70 22.30
    Heating::Air+7°C - Water 47/55°C - Rated power input kW 8.78 10.40 12.20 14.10
    Heating::Air+7°C - Water 47/55°C - COP 1.22 1.30 1.37 1.58
    Indoor unit
    Outdoor unit::Airflow (LS/MS/HS/SS) m³/h 10650 10650 11200 11200
    Outdoor unit::Dimensions (WxHxD) mm 1129x1558x440 1129x1558x440 1129x1558x440 1129x1558x440
    Outdoor unit::Net Weight kg 177/206 177/206 177/206 177/206
    Code 7HP061085 7HP061086 7HP061087 7HP061088
    Energy label
    Alimentation
    Power supply::Phase/Voltage/Frequency 3P/380-415V/50Hz 3P/380-415V/50Hz 3P/380-415V/50Hz 3P/380-415V/50Hz
    Power supply::Max. current A 21.00 24.50 27.00 28.50
    Actions Request a quote Request a quote Request a quote Request a quote
  • Accessories and options
  • Bizone Kit 2Z2T

    Bizone Kit 2Z2T

    Réf. : 7ACEL1882

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    This module makes it simple to manage 2 zones with 2 different temperatures (e.g.: floor heating & radiator).
    All the components are pre-wired, you just have to plug them in.
    1 hydraulic module:
    - 2 condensate pumps
    - 1 regulator
    - 2 thermostats (radio)
    - 1 outdoor temperature sensor (radio)
    - 1 antenna (for radio connection)
    Thermostat functions:
    - Temperature change (5 C to 37 C)
    - Mode switch (heating / air conditioning)
    - Weekly programming
    - Holiday mode

    Hydraulic compensator

    Hydraulic compensator

    Réf. : 7ACFH0854

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    To be use with the Bizone Kit.
    If you don’t have a buffer tank you can use this compensator. Easy to pair with our
    Bizone Kit.
    14 kW ∆T 5°C – 28 kW ∆T 10°C

    3 ways valve

    3 ways valve

    Réf. : 7ACFH0855

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    3 ways valve for heating and DHW

    Magnetic dirt separator 1’’

    Magnetic dirt separator 1’’

    Réf. : 7ACFH0856

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Dirt separator, swiveling, with magnetic ring

    Antifreeze valve MM 1"

    Antifreeze valve MM 1

    Réf. : 7ACFH0857

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Ready to install
    Thermostatic valve
    Automatic opening (+ 3 ° C) and closing (+ 4 ° C) (+/- 1 ° C)

    Automatic air vent 1"

    Automatic air vent 1

    Réf. : 7ACFH0862

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Continuous degassing of air present in the hydraulic circuit
    Automatic operation
    Swivelling: horizontal or vertical mounting

    Mix bottle 25 L

    Mix bottle 25 L

    Réf. : 7ACFH0859

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Insulated bottle, reversible: heating and cooling
    ErP class: C
    Usable volume: 25 L
    Wall installation

    Mix bottle 50 L

    Mix bottle 50 L

    Réf. : 7ACFH0858

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Insulated bottle, reversible: heating and cooling
    ErP class: C
    Usable volume: 51 L
    Wall installation

    Mix bottle 100 L

    Mix bottle 100 L

    Réf. : 7ACFH0860

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Insulated bottle, reversible: heating and cooling
    ErP class: C
    Usable volume: 95 L
    Floor installation

    Mix bottle 200 L

    Mix bottle 200 L

    Réf. : 7ACFH0861

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Insulated bottle, reversible: heating and cooling
    ErP class: C
    Usable volume: 195 L
    Floor installation

    Safety valve 10B 20X27

    Safety valve 10B 20X27

    Réf. : 7ACFH0863

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Installation power: 46 kW
    Graduated adjustment scale: 0.1 to 0.6 bar differential

    Expansion vessel 12 L

    Expansion vessel 12 L

    Réf. : 7ACFH0864

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    CE standard vessel for heating and cooling circuit
    Capacity: 12 L
    Pre-inflation: 1 bar

    Expansion vessel 18 L

    Expansion vessel 18 L

    Réf. : 7ACFH0865

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    CE standard vessel for heating and cooling circuit
    Capacity: 18 L
    Pre-inflation: 1 bar

    Wall support for expansion vassel

    Wall support for expansion vassel

    Réf. : 7ACFH0866

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Arm, vessel bracket, equipped with:
    - quick-release coupling for vessel
    - PR2 air bleed
    - NC valve with pressure gauge

    Backflow preventer 1/2

    Backflow preventer 1/2

    Réf. : 7ACFH0867

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Non-controllable reduced pressure zone backflow preventer
    NF

    Condensate pump EVOSTA 2 - 4 to 7 mH2O 180 mm

    Condensate pump EVOSTA 2 - 4 to 7 mH2O 180 mm

    Réf. : 7ACFH0868

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Low consumption electronic circulator (EEI <= 0.18)
    For heating and air conditioning
    With limescale protection during commissioning
    5 year warranty
    Flowrate: 0.4 to 3.6 m3 / h
    Manometric head: 4 to 6.9 mWp
    3 operating curves each with 3 speeds:
    - Proportional differential pressure
    - Constant differential pressure
    - Constant speed
    Protection class: IP X5

    Axial thermometer 100 immersion 200

    Axial thermometer 100 immersion 200

    Réf. : 7ACFH0869

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Axial thermometer
    Display 0/120°

    Shock absorder (support)

    Shock absorder (support)

    Réf. : 7ACTL0510

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Helps reduce the transmission of vibrations.
    Length: 1 000mm

    Line electrical heater - 3kW

    Line electrical heater - 3kW

    Réf. : 7ACFH0822

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Provides additional heating when the heating demand is greater than the heat pump capacity

    Remote control RCW29

    Remote control RCW29

    Réf. : 7ACEL1896

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    On/Off control, additional heating
    Operating mode: cooling / heating / automatic
    DHW parameters: forced mode / holiday / anti-legionella / DHW pump
    Temperature parameter: water outlet, set temperature
    Timer: 12/24h
    On/Off timer, daily / weekly
    Display of different temperatures
    Probe values display
    Fault codes
    Maintenance mode

    Temperature sensor

    Réf. : 1PR070230

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Temperature sensor + cable (10m)

    Cable extension (mixing tank)

    Réf. : 7ACFH0870

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Connection between temperature sensor and electronic board for mixing tank probe

    Cable extension (solar)

    Réf. : 7ACFH0871

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Connection between temperature sensor and electronic board for solar probe

    DHW electric heater control panel

    Réf. : 7ACEL1892

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Control the DHW electric heater with the heat pump

    DHW TANK 200L

    DHW TANK 200L

    Réf. : 7ACFH0872

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    DHW tank 200L

    DHW TANK 200S

    DHW TANK 200S

    Réf. : 7ACFH0876

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    DHW tank 200S

    DHW TANK 300L

    DHW TANK 300L

    Réf. : 7ACFH0873

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    DHW tank 300L

    DHW TANK 300S

    DHW TANK 300S

    Réf. : 7ACFH0875

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    DHW tank 300S

    DHW TANK 500L

    DHW TANK 500L

    Réf. : 7ACFH0874

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    DHW tank 500L

    DHW TANK 500S

    DHW TANK 500S

    Réf. : 7ACFH0877

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    DHW tank 500S
  • Technical documentation

These products

may also be interested for you

Wellea WT

Split heat pump with DHW tank included

Split heat pump with DHW tank included

Wellea WT
See the product

DFMO

Water-loop heat pump

Water-loop heat pump

DFMO
See the product

XDLF

Dual-flow console multisplit

Dual-flow console multisplit

XDLF
See the product

TDF Eleo

Thermodynamic water heater

Thermodynamic water heater

TDF Eleo
See the product

WFAE

Window

Window

WFAE
See the product

FlowLogic III

Outdoor unit - 2-way top discharge

Outdoor unit - 2-way top discharge

FlowLogic III
See the product

Are you an individual ?

Airwell general public