Wellea Monoblock

Monoblock Heat pump

Système monobloc

The + "sustainable development":

  • High energy class A+++

The + "user":

  • Compatible with all emitters
  • Great flexibility of use
  • Perfect for replacing an oil or gas burner

The + "installer":

  • Customisable water program, allowing the entire heating circuit to be managed using the many available connections

The + "technology":

  • Operates at outdoor temperatures down to -25 °C
  • HP Keymark certified
  • Characteristics products
  • Unités intérieures AW-WHPM05-H91 AW-WHPM07-H91 AW-WHPM09-H91 AW-WHPM12-H91 AW-WHPM14-H91 AW-WHPM16-H91 AW-WHPM12-H93 AW-WHPM14-H93 AW-WHPM16-H93 AW-WHPMA04-H91 AW-WHPMA06-H91 AW-WHPMA08-H91 AW-WHPMA10-H91
    Unités extérieures 1
    ~230V - 50Hz
    Unités extérieures 3
    ~400V - 50Hz - N
    Cooling
    Cooling::Operating limits °C -5/43 -5/43 -5/43 -5/46 -5/43 -5/43 -5/43 -5/43 -5/43 -5/43 -5/43 -5/43 -5/43
    Cooling::Air 35°C - Water ind. 12°C /out. +7°C - Heating capacity kW 4.85 6.3 7.95 10.9 12.4 14 11.5 12.4 14 4.7 7 7.45 11.5
    Cooling::Air 35°C - Water ind. 12°C /out. +7°C - Rated power input kW 1.63 2.27 3.15 3.74 4.96 5.6 4.18 4.96 5.6 1.36 2.33 2.22 4.18
    Cooling::Air 35°C - Water ind. 12°C /out. +7°C - EER 2.98 2.77 2.53 2.92 2.5 2.5 2.75 2.5 2.5 3.45 3 3.35 2.75
    Cooling::Air 35°C - Water ind. 23°C /out. +18°C - Heating capacity kW 4.6 6.45 8 12.2 13.5 14.9 12 13.5 14.9 4.5 6.5 8.3 12
    Cooling::Air 35°C - Water ind. 23°C /out. +18°C - Rated power input kW 0.95 1.39 1.92 2.55 3.75 4.38 3.04 3.75 4.38 0.82 1.35 1.64 3.04
    Cooling::Air 35°C - Water ind. 23°C /out. +18°C - EER 4.82 4.65 4.16 4.78 3.6 3.4 3.95 3.6 3.4 5.5 4.8 5.05 3.95
    Indoor unit
    Outdoor unit::Airflow (LS/MS/HS/SS) m³/h 3050 3050 3050 6150 4060 4650 4060 4060 4650 2770 2770 4030 4060
    Outdoor unit::Dimensions (WxHxD) mm 1210x945x402 1210x945x402 1210x945x402 1404x1414x405 1385x945x526 1385x945x526 1385x945x526 1385x945x526 1385x945x526 1295x792x429 1295x792x429 1385x945x526 1385x945x526
    Outdoor unit::Net Weight kg 92/110 92/110 92/110 163/183 144/170 144/170 160/188 160/188 160/188 98/121 98/121 121/148 144/170
    Code 7HP061015 7HP061016 7HP061017 7HP061018 7HP061019 7HP061020 7HP061056 7HP061057 7HP061058 7HP061075 7HP061076 7HP061077 7HP061078
    Energy label
    Plages de fonctionnement
    Performances::Energy label - Water outlet à 35°C ηs/classe 176%/A+++ 176%/A+++ 177%/A+++ 169%/A++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
    Performances::Energy label - Water outlet à 55°C ηs/classe 127%/A++ 127%/A++ 126%/A++ 126%/A++ A++ A++ A++ A++ A++ A++ A++ A++ A++
    Performances::SCOP (average climate) - Water outlet à 35°C 4.47 4.47 4.51 4.29 4.72 4.62 4.81 4.72 4.62 4.85 4.95 5.21 4.81
    Performances::SCOP (average climate) - Water outlet à 55°C 3.24 3.24 3.22 3.23 3.47 3.41 3.45 3.47 3.41 3.31 3.52 3.36 3.45
    Performances::SEER (average climate) - Water outlet à +7°C 4.71 4.99 4.92 4.85
    Performances::SEER (average climate) - Water outlet à +18°C 7.61 8.58 7.88 7.5
    Performances::Sound level dB(A) 48.8 52.3 54.5 57.6 54 58 54 54 58 45 48 49 53
    Performances::Sound pressure level (1m) dB(A) 61 64 67 68 65 68 65 65 68 55 58 59 65
    Alimentation
    Alimentation::Phase/Voltage/Frequency 1P/220-240V/50Hz 1P/220-240V/50Hz 1P/220-240V/50Hz 1P/220-240V/50Hz 1P/220-240V/50Hz 1P/220-240V/50Hz 3P/380-415V/50Hz 3P/380-415V/50Hz 3P/380-415V/50Hz 1P/220-240V/50Hz 1P/220-240V/50Hz 1P/220-240V/50Hz 1P/220-240V/50Hz
    Alimentation::Fuse rating am A 25 25 25 30 39 40 23 24 25 12 14 29 38
    Alimentation::Integrated electrical resistor kW - - - 3 3 3 9 9 9 0 0 3 3
    Actions Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote Request a quote
  • Accessories and options
  • Bizone Kit 2Z2T

    Bizone Kit 2Z2T

    Réf. : 7ACEL1882

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    This module makes it simple to manage 2 zones with 2 different temperatures (e.g.: floor heating & radiator).
    All the components are pre-wired, you just have to plug them in.
    1 hydraulic module:
    - 2 condensate pumps
    - 1 regulator
    - 2 thermostats (radio)
    - 1 outdoor temperature sensor (radio)
    - 1 antenna (for radio connection)
    Thermostat functions:
    - Temperature change (5 C to 37 C)
    - Mode switch (heating / air conditioning)
    - Weekly programming
    - Holiday mode

    Hydraulic compensator

    Hydraulic compensator

    Réf. : 7ACFH0854

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    To be use with the Bizone Kit.
    If you don’t have a buffer tank you can use this compensator. Easy to pair with our
    Bizone Kit.
    14 kW ∆T 5°C – 28 kW ∆T 10°C

    3 ways valve

    3 ways valve

    Réf. : 7ACFH0855

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    3 ways valve for heating and DHW

    Magnetic dirt separator 1’’

    Magnetic dirt separator 1’’

    Réf. : 7ACFH0856

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Dirt separator, swiveling, with magnetic ring

    Antifreeze valve MM 1"

    Antifreeze valve MM 1

    Réf. : 7ACFH0857

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Ready to install
    Thermostatic valve
    Automatic opening (+ 3 ° C) and closing (+ 4 ° C) (+/- 1 ° C)

    Automatic air vent 1"

    Automatic air vent 1

    Réf. : 7ACFH0862

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Continuous degassing of air present in the hydraulic circuit
    Automatic operation
    Swivelling: horizontal or vertical mounting

    Mix bottle 25 L

    Mix bottle 25 L

    Réf. : 7ACFH0859

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Insulated bottle, reversible: heating and cooling
    ErP class: C
    Usable volume: 25 L
    Wall installation

    Mix bottle 50 L

    Mix bottle 50 L

    Réf. : 7ACFH0858

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Insulated bottle, reversible: heating and cooling
    ErP class: C
    Usable volume: 51 L
    Wall installation

    Mix bottle 100 L

    Mix bottle 100 L

    Réf. : 7ACFH0860

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Insulated bottle, reversible: heating and cooling
    ErP class: C
    Usable volume: 95 L
    Floor installation

    Mix bottle 200 L

    Mix bottle 200 L

    Réf. : 7ACFH0861

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Insulated bottle, reversible: heating and cooling
    ErP class: C
    Usable volume: 195 L
    Floor installation

    Safety valve 10B 20X27

    Safety valve 10B 20X27

    Réf. : 7ACFH0863

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Installation power: 46 kW
    Graduated adjustment scale: 0.1 to 0.6 bar differential

    Expansion vessel 12 L

    Expansion vessel 12 L

    Réf. : 7ACFH0864

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    CE standard vessel for heating and cooling circuit
    Capacity: 12 L
    Pre-inflation: 1 bar

    Expansion vessel 18 L

    Expansion vessel 18 L

    Réf. : 7ACFH0865

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    CE standard vessel for heating and cooling circuit
    Capacity: 18 L
    Pre-inflation: 1 bar

    Wall support for expansion vassel

    Wall support for expansion vassel

    Réf. : 7ACFH0866

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Arm, vessel bracket, equipped with:
    - quick-release coupling for vessel
    - PR2 air bleed
    - NC valve with pressure gauge

    Backflow preventer 1/2

    Backflow preventer 1/2

    Réf. : 7ACFH0867

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Non-controllable reduced pressure zone backflow preventer
    NF

    Condensate pump EVOSTA 2 - 4 to 7 mH2O 180 mm

    Condensate pump EVOSTA 2 - 4 to 7 mH2O 180 mm

    Réf. : 7ACFH0868

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Low consumption electronic circulator (EEI <= 0.18)
    For heating and air conditioning
    With limescale protection during commissioning
    5 year warranty
    Flowrate: 0.4 to 3.6 m3 / h
    Manometric head: 4 to 6.9 mWp
    3 operating curves each with 3 speeds:
    - Proportional differential pressure
    - Constant differential pressure
    - Constant speed
    Protection class: IP X5

    Axial thermometer 100 immersion 200

    Axial thermometer 100 immersion 200

    Réf. : 7ACFH0869

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Axial thermometer
    Display 0/120°

    DHW TANK 200L

    DHW TANK 200L

    Réf. : 7ACFH0872

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    DHW tank 200L

    DHW TANK 300L

    DHW TANK 300L

    Réf. : 7ACFH0873

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    DHW tank 300L

    DHW TANK 300S

    DHW TANK 300S

    Réf. : 7ACFH0875

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    DHW tank 300S

    Shock absorder (support)

    Shock absorder (support)

    Réf. : 7ACTL0510

    Appareils : WELLEA WT/WELLEA Split/WELLEA Monobloc/WELLEA Monobloc DF

    Helps reduce the transmission of vibrations.
    Length: 1 000mm
  • Technical documentation

These products

may also be interested for you

Wellea Monoblock

Monoblock Heat pump

Monoblock Heat pump

Wellea Monoblock
See the product

Wellea Monoblock DF

Monoblock Heat pump

Monoblock Heat pump

Wellea Monoblock DF
See the product

Are you an individual ?

Airwell general public